Skip to content

01Service

Fire door surveys.

Condition assessments and compliance audits for fire doors in residential, commercial and managed buildings, with a written report you can act on.

—Overview

How we approach surveys.

A fire door only performs as tested when every part of it is right: the leaf, frame, gaps, seals, hinges, closer, glazing and signage. Our surveys examine each door individually and record what we find, so that the responsible person has a clear picture of the condition of their doors and of any work that is needed.

Surveys are carried out with reference to the Regulatory Reform (Fire Safety) Order 2005, BS 8214 and, where they apply to your building, the Fire Safety (England) Regulations 2022. We report what we see and explain why it matters, without overstating risk or recommending work that is not required.

Who it is for

Building owners, managing agents, housing providers, HMO landlords, facilities managers and anyone acting as the responsible person for a building.

Two members of the Cochrane Doors team in branded T-shirts assessing a door opening on site

—What's included

The work, in detail.

  • 01.1

    Door-by-door inspection

    Each door is referenced and located on a schedule, with its fire rating and any certification evidence noted.

  • 01.2

    Gap and seal checks

    Leaf-to-frame and threshold gaps measured; intumescent and smoke seals checked for presence, condition and continuity.

  • 01.3

    Ironmongery and closers

    Hinges, locks, latches and self-closing devices checked for function, fixings and suitability for fire door use.

  • 01.4

    Glazing and apertures

    Vision panels, transfer grilles and letter plates reviewed for appropriate fire-rated components.

  • 01.5

    Photographic evidence

    Every defect recorded with dated photographs, referenced to the door schedule.

  • 01.6

    Prioritised recommendations

    A clear action for each door — no action, adjust, repair or replace — with the reasoning set out.

—Documentation

What you receive.

Clear records are part of the service. Everything is provided in a format you can keep with your fire safety documentation.

  • 01A written survey report (PDF)
  • 02A door schedule for your records
  • 03Photographs referenced to each door
  • 04An itemised quotation for remedial works, on request

—Get in touch

Start with a conversation.

Tell us about the building and what you need. We will explain the options clearly and arrange a survey where it is useful.